Specifications:
Rated Power |
600W |
||||||||||
Input(DC) |
|||||||||||
PV open voltage range |
26V-45V |
39V-60V |
55V-90V |
85V-130V |
120-180V |
||||||
PV MAX input power(W) |
7000W |
||||||||||
MPPT Voltage range(V) |
22-34VDC |
33-47VDC |
44V-70VDC |
66-100VDC |
90-140V |
||||||
MPP tracking efficiency |
>99% |
||||||||||
MAX.DC current(A) |
30A |
20A |
15A |
10A |
10A |
||||||
Suitable for Battery voltage(V) |
24V |
36V |
48V |
72V |
96V |
||||||
Battery Low Voltage Protection(V) |
22V |
33V |
44V |
66V |
88V |
||||||
Output(AC) |
|||||||||||
PV mode AC MAX output (W) |
500 |
||||||||||
Battery mode Max output power |
450W |
450W |
450W |
450W |
450W |
||||||
AC output range |
220VAC(190-260VAC) or 120VAC(90-135VAC) |
||||||||||
Frequency range |
50Hz(48~52) or 60Hz(58~62) |
||||||||||
Power Factor |
>98% |
||||||||||
THD |
<5% |
||||||||||
Phase Shift |
<1% |
||||||||||
Stable real efficiency / 120V |
87% |
88% |
89% |
89% |
91% |
||||||
Stable real efficiency / 220V |
88% |
89% |
91% |
92% |
94% |
||||||
Other electrical data |
|||||||||||
Protection |
Islanding; Short-circuit; Low Voltage; Over Voltage; Over temperature Protection |
||||||||||
Work Temperature |
‘-25°C~ 80°C |
||||||||||
Work Humidity |
0%~90%RH non-condensing |
||||||||||
Grade of Waterproof |
Outdoor design IP22 |
||||||||||
LED Show |
R&G&B LED |
||||||||||
Cooling |
Fan |
||||||||||
Stand-by Power |
<1W |
||||||||||
Matching component: |
Monocrystalline ,polycrystalline , thin-film solar panels. |
||||||||||
Mechanical data |
|||||||||||
Net Weigtht |
2.2kgs/pc |
||||||||||
Gross Weight |
2.5kgs/pc |
||||||||||
Machine size(LxWxH) |
22.2×16.2×6.5CM |
||||||||||
Packing Size (LxWxH) |
32x22x12CM |
PV grid-connected inverter operating mode
The grid-tied inverter has an automated working order, without needing to monitor. On detection the power output from solar panels, device will decide if the power was large enough to begin the conversion process. Coversion process includes 5 modes, Startup, Grid-tied begin, Standby, Stop, Fault-find.
Startup – When the start button is on, solar panel and grid lines both connected in normal condition, inverter enters working condition.
Grid-tied begin – Grid-tied begin mode is when inverter starts to convert the Direct Current fed through from PV solar panel to a stable Alternate Current and flow to the utility grid. To enable the maximum output of energy, the device uses MPPT control technology to track sun rays, this technology promises the maximum efficiency under diferent daylight and temperature conditions.
Standby – Standby mode is when device detects insufficient power feeding through from the solar panel, or device detects abnormal status such as voltages, frequencies, and temperatures not in the permitted range, the device enters standby mode.
Stop – Insufficient sunlight hence insufficient PV power feeding through to the device and device enters into the standby mode, when this condition continues and DC voltages falls below 12V for over 1 minute, the device will enter Stop mode.
When error ocurs, fault find indicator starts flashing, device will enter Stop mode. Please see 3.4 error status on LED indicator.
(Battery) discharge and grid mode(With ADJ function models)
1.The DC input of the system can be directly connected with the battery, Turn the knob of the inverter to the right into the battery mode, then the tracking function will be turned off, the output power will be adjusted from left to right, At this point the output power can be adjusted from 80W-450W or so arbitrary output to ensure that the inverter can work for a long time in the grid status.
2. When the inverter connected to the battery discharge, if the battery voltage is too low, the inverter will automatically stop and cut off grid output to protect the battery over discharge to extend battery life.
3.Different specifications of the input voltage of the inverter will be used with different voltage battery, the battery voltage protection point please refer to the following
Battery voltage |
Inverter Input |
Battery Low voltage protection |
Battery high voltage protection |
12V battery |
16V~28V |
11V |
14.5V |
24V battery |
26V~45V |
21V |
29V |
36V battery |
40V~62V |
33V |
43.5V |
48V battery |
55V~90V |
44V |
58V |
60V battery |
48V~86V |
55V |
72.5V |
72V battery |
85V~130V |
66V |
87V |
96V battery |
120V-180V |
88V |
120V |
4 GREAT REASONS TO BUY FROM US:
- Over 37,000 happy customers worldwide
- Real people on our support team ready to help
- The finest materials and stunning design — all our products are developed with an obsessive dedication to quality, durability, and functionality
- We use the most secure online ordering systems on the market, and are constantly improving our software to make sure we offer the highest possible security
BUY WITH CONFIDENCE
Our mission is to make your shopping experience as safe and enjoyable as possible. Have questions? Feel free to contact our award-winning customer care team for advice on everything from product specifications to order tracking.
- Money back guarantee: Something not quite right? If you’re not totally satisfied with your purchase, you can return it within 15 days for a full refund
- Risk-Free Purchase: We utilize industry-standard Secure Sockets Layer (SSL) technology to allow for the encryption of all the sensitive information, so you can be sure your details are completely safe with us
- Trustworthy payment method: We partner with the most popular online payment solutions that guarantee enhanced security and fast transaction processing