1000W Battery discharge mode/LCD Solar Grid Tie inverter With built-in power limiter, MPPT pure sine wave on grid inverter DC22-6V/45-90V to AC110V/ 230V
G2 (Generation 2) SUN Series Grid Tie Power Inverter Limit Function User Manual
Why our grid tie inverters need limitfunction? — It is in response to the overwhelming clamor from our customers
for
a function that can control the amount of power that the grid tie
inverters can generate.With this function, the inverters will just
generate power that is not larger than the loads’ power even the
inverters are connected with big power solar panel array, we call it
“limit function”
Because in some countries, the producer pays for the excess power it gives to the distribution grid. This is because
the
electric power meter(the one provided by the electricity provider in
the area) is not aware of the direction of power flow. In other words it
only adds even if power is exported to the grid, thus, the consumer
will be charged for power even if it is given to the grid, and this is
the problem.
Our SUN G2 series grid tie inverters are integrated this limit function, so SUN G2 series inverters can work in limit mode
or normal mode(no limit), you can make the configuration on the LCD display.
The limit sensor should be clamped on the live line at the position before the loads' access points, and the inverter's
access
point can be at any position on the same live line, see picture 1. The
inverter with the limit function will just generate power that is less
than total power consumption by loads that are connected after the
position that the limit sensor clamped. The inverter will not measure
loads’ power that connected before the point of the limit sensor
clamped.
Connecting method for three phases AC grid
If your AC grid is three phases grid, and you have more SUN G2 grid tie inverters, then you
can
connect inverters to three phases individually. Please see picture 2.
These three inverters will not affect each other. Gline will be
connected as normal, so not shown in picture 2.
Connecting more than one inverter on onelive line:
If
you want to use more inverters on one live line to generate more power
and also need limit function, you can connect inverters like picture
3(for two inverters). The two inverters will not produce the same power,
but limit function is still available. G line will be connected as
normal, so not shown in picture 3.
Limit function for the US split phase AC grid.
First connecting method for SUN-2000G2(Suggested)
The
inverter should be connected to compensate for 240V loads. Because the
inverter will generate the same value feed current at L1 and L2, and
240V loads also consume the same value current at L1 and L2, so with the
limit function of the inverter, the inverter will just produce power
that is same as or less than 240V loads’ power, there will be no extra
countercurrent feeding to the AC grid. So if the 240V loads were
connected at separate lines and not mixed with 120V loads, you can
connect the inverter and clamp the limit sensor as picture4.
Picture 4: Connecting method for Compensating 240V loads’ power at a separate live line
Second connecting method for SUN-2000G2(Suggested)
If 240V loads and 120V loads were connected on the same live lines, but 240V loads were connected after
120V loads, the best connecting method is clamping the limit sensor on the live line at the position after the
120V loads and before 240V loads. The inverter can be connected at any position on the live lines, See picture 5.
Because the inverter will produce the same value feed current at L1 and L2, and 240V loads also consume the same
value
current at L1 and L2, so with the limit function of the inverter, the
inverter will just produce power that is same as or less than 240V
loads’ power, there will be no extra countercurrent feeding to the AC
grid.
Third connecting method for SUN-2000G2(Can be used, but not suggested)
If 120V loads and 240V loads were mixed, and the 240V loads were connected before 120V loads, the inverter
and limit sensor can be installed as picture 6.
With this connecting method, because the total loads' consumption at L1 and L2 will not be the same, but
the inverter will just produce the same value feed current at L1 and L2, so the limit sensor must clamp at the
L1 or L2, which total loads’ power is smaller, this will prevent extra countercurrent feeding to the AC grid,
otherwise, there will be extra countercurrent feeding to the AC grid if the inverter can produce enough current to
compensate the larger current at L1 or L2. If you connect a system like picture 3, loads' power at L1 must be less
than loads' power at L2, otherwise, the limit sensor should clamp at L2.
Using two SUN-1000G2 inverters to connect with US split phase AC grid(Good solution)
Using two SUN-1000G2 inverters to compensate L1 and L2 loads’ current individually, with this method, the
inverters'
limit function can work very well, there will be no extra
countercurrent feeding to the AC grid from L1and L2, see picture 7. You
also can just connect one SUN-1000G2 unit with a limit sensor at one of
the live lines.
Important information:
After Having connected the inverters and limit sensors as one method listed above, If you want to use
limit function, you also need to do below configuration on LCD display, You should select “Internal Limiter”
as picture 8.
If the display shows as picture 9, this means the limit sensor is not connected well, or there are no loads
powered on, you can check the limit sensor and switch on some loads. If there is no loads’ power, the
inverter will not produce power under the limit model.
If
the display shows as picture 10, the AC grid power is negative, this
means the clamping orientation of the sensor is not correct
If so, you need to clamp the limit sensor in the opposite direction as picture 11.
If you did everything correctly, the LCD display should show as picture 12.
The inverter just produces almost the same power as the loads' power, so the AC grid just consumes very
small power if the inverter can produce enough power to compensate the loads' power.
(Remark: Numbers on the LCD display will be different for different inverter and different using environment.)
Packing list:
2000W Grid tie inverter—-1pcs;
AC cable—-1pcs;
clamp sensor with 2m cable—1pcs;(Optionals ,only for those model with limiter function,cable could be extended with extra cost)
WIFI plug—1pcs(Optional,only for those models with WIFI function)
English Manual—1pcs
you receive an item DOA (damage on arrival) or a defects products,
please contact us. A replacement or refund will be offered after
communication. Some low-valued items might not be returned.
prove it we offer a FREE Six-MONTH limited warranty. Please read the
following important details regarding the Warranty Policy.
does not apply to conditions resulting from misuse, abuse, negligence,
accident, improper application, improper installation or alteration.
DO contact us first if there is any problem with payment, delivery or
products received. Negative feedback will do no help to solve the
problem.
Shipping & Handing
Time of Arrival)displayed in the listing is given by shipping companies
but that can not be as reason of delivery delayed dispute. We will NOT
be responsible for any delay during delivery including but not limited
to customs postage checking, strike, force majeure etc.
buyers were required to fill in the full name; Brazilian buyers are
required to leave CPF/CPNJ Number; Chilean buyers are required to leave
RUT number
4 GREAT REASONS TO BUY FROM US:
- Over 37,000 happy customers worldwide
- Real people on our support team ready to help
- The finest materials and stunning design — all our products are developed with an obsessive dedication to quality, durability, and functionality
- We use the most secure online ordering systems on the market, and are constantly improving our software to make sure we offer the highest possible security
BUY WITH CONFIDENCE
Our mission is to make your shopping experience as safe and enjoyable as possible. Have questions? Feel free to contact our award-winning customer care team for advice on everything from product specifications to order tracking.
- Money back guarantee: Something not quite right? If you’re not totally satisfied with your purchase, you can return it within 15 days for a full refund
- Risk-Free Purchase: We utilize industry-standard Secure Sockets Layer (SSL) technology to allow for the encryption of all the sensitive information, so you can be sure your details are completely safe with us
- Trustworthy payment method: We partner with the most popular online payment solutions that guarantee enhanced security and fast transaction processing