MH1210W LED Digital Temperature Controller Thermostat Thermoregulator Incubator Relay LED 10A Heating Cooling 12V 24V 110V 220V
Feature:
1>Micro thermostat.
2>With large and clear LED display, better readability.
3>Wide temperature measurement range.
3> Heating and cooling control.
4>Temperature calibration function.
5> Delay protection function.
6> All parameters can be set to default settings after short circuit.
7>It can be used in household refrigerators, water tanks, refrigerators, industrial chillers, boilers, steamers, industrial equipment and other temperature control systems.
Specifications:
1>Working voltage: 90~250V±10%
2>Rated current: 10A
3>Power consumption: ≤3W
4>Measuring range: -50~110 degrees Celsius
5>Measurement accuracy: 0.1 degrees Celsius
6>Measurement error: ±0.3 degrees Celsius
7>Control accuracy: 0.1 degrees Celsius
8>Working temperature: -20~70 degrees Celsius
9>Temperature sensor: NTC 25 degrees Celsius = 10K B3435
10>Product size: 8.5 * 7.5 * 3.5cm / 3.4 * 3 * 1.4in
Instructions:
Press the S key for 3 seconds to enter the program menu code mode, which displays the code HC. Press the △ or ▽ key to cycle through the HC-CP-LA-PU-CA parameters. To enter a code, press the S key, press the △ or ▽ key to change the desired value and press SET to save and exit. . Control temperature setting: Short press S key (not more than 2 seconds) to display the factory default control temperature. Press △ or ▽ key to change the value well to save automatically. (Press and hold the △ or ▽ key for 2 seconds to quickly adjust the value.)
Heating control:
When the temperature control method (code HC) is set to H, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≥ the set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≤ the set temperature value (28 ° C) – the return temperature (2 ° C) and the “delay” is set After the start time, the relay pulls up to start the output load; (if the delay function is not needed, the delay start (code PU) can be set to 0).
Cooling mode:
When the temperature control method (code HC) is set to C, for example, the set control temperature value is 28 ° C, and the temperature difference is 2 ° C. When the ambient temperature value ≤ set temperature value (28 °C), the relay opens and closes the output load; when the ambient temperature value ≥ set temperature value (28 °C) + hysteresis temperature (2 ° C) and the “delay start” is set After the time, the relay is sucked and the output load is started: (It is recommended that the delay start time is the default time to protect the compressor. If no delay is required, the code (PU) is set to 0)
Menu Code Table:
![](http://ae01.alicdn.com/kf/H26219e266d17400ea06c56d84cf955f01.jpg)
Product schematic
![](http://ae01.alicdn.com/kf/H35d14c20ea8c40158da86d796dc54c13d.jpg)
Product size chart
![](http://ae01.alicdn.com/kf/Ha4460081b35b44fb979f28ea093e5a9fX.jpg)
Package includes:
1 x Temperature controller
1 x Temperature sensor
1 x Instruction manual