AC110-220 W1212 Digital Temperature Humidity Controller Timer SHT20 Sensor Probe for Incubator Aquarium Thermostat Humidistat

16-31 days
Quantity:
In Stock
View Cart
Guaranteed safe checkout
Product/Services Details - For Bulk purchase Contact 0805 555 5061
Item Specifics For More details Contact 0805 555 5061
Product/Services Details - For Bulk purchase Contact 0805 555 5061

81088

recommend

 
 

W1212 intelligent digital display high-precision temperature and humidity controller AC110-220 SHT20 sensor

Note: The product has a clock function with a battery. The product is shipped without a battery. The customer needs to buy the battery by himself. The battery model: CR1220 3V button. The battery needs to be calibrated for the first time.
Time calibration operation mode:
1. In the case of power on, long press the setting key to enter the setting interface, short press the setting key to quickly switch (P/F/H), set the time to H, and select H1-H5 by the up and down keys. If you need real-time clock setting, select the corresponding H1 item, short press the power button to enter the setting time, the up button is to increase, the down button is to decrease, and the power button is to confirm
Instructions for setting operation:
In the case of power on, long press the setting button to enter the setting interface, short press in the setting interface to quickly switch (P/F/H), you can use the up and down keys to select P1-P5/F1-F4/H1-H5, and then short press The power button is OK to enter the setting parameters
Specification:
Product name: Intelligent temperature and humidity controller
Product model: W1212
Power supply voltage: AC110 -220V
Working frequency: 50HZ
Measuring range: -40 -120°C 0 -00%RH
Measurement accuracy: temperature ± 0.3°C, humidity ± 3%RH
Sensor cable length: 100CM
Size: 79.5*43*36mm
Shell material: surface shell ABS, bottom shell flame retardant ABS
Tips:
①In normal mode, short press the setting key or plus and minus keys to view the setting parameters, it will return to normal mode after 1 second.
②In the setting mode, if no key is pressed, it will automatically return to the normal working mode after 10 seconds.
③In the setting mode, when a certain option value is set, if the power button is not pressed to confirm the return, it will automatically return to the normal working mode after 10 seconds, and the value will not be saved.
Key Description:
1. Power button:
①Long press the switch
②In the setting mode, short press is the confirmation key
2. Setting key:
①Short press to view the temperature control mode, short press again to view the humidity control mode
②Long press to enter the setting interface, short press the setting button in the setting interface to select temperature control and humidity control or time mode (that is, P and F and H mode switching)
3. + key:
① On the homepage, short press to view the target temperature switch time, long press to turn on the target temperature switch time
②In the menu mode, short press and 1 long press and continue to add
4.-Key: ① Short press to view the target humidity switch time on the homepage, long press to turn on the target humidity switch time
②In the menu mode, short press to decrease 1 and long press to continue to decrease
5. Combination key: setting key + number minus (restore factory settings)
In the power-on state, pressing and holding the key combination at the same time will restore the factory settings
Mode description:
Both heating and cooling in temperature control mode and humidification and dehumidification in humidity control mode need to be set manually
Temperature control mode:
1. Cooling mode: (You can short press the setting button on the home page to view, or you can see the snowflake sign on the screen, that is, the current cooling mode)
①When the real-time temperature ≥ the target temperature setting value (OBJ TEMP) + the temperature difference setting value, it enters the cooling state, the relay works, and the cooling starts.
②When the real-time temperature drops to the target temperature setting value (OBJTEMP), the refrigeration relay stops working, the thermostat enters the temperature control state, and the temperature control range is the temperature difference setting value.
③When the real-time temperature ≥ the target temperature setting value (OBJ TEMP) + the temperature difference setting value, the thermostat enters the compressor delay state, and the refrigeration relay starts to work after the compressor delay.
2. Heating mode: (You can short press the setting button on the home page to view, or the sun symbol can be seen on the screen, that is, the current heating mode)
① When the real-time temperature is less than the target temperature setting value-the temperature difference setting value, it enters the heating state and the heating relay works.
②When the heating temperature reaches the target temperature value, the heating relay stops working, the thermostat enters the temperature control state, and the temperature control range is the temperature difference set value.
Humidity control mode:
1. Dehumidification mode: (You can short press the setting button on the home page to view, or you can see the prohibition of water droplets on the screen, that is, the current dehumidification mode)
①When the real-time humidity and humidity temperature difference value (OBJ HUM) ≥ the target humidity value, the relay starts to work and starts dehumidification
②When the dehumidification humidity reaches the target humidity value, the dehumidification relay stops working and enters the humidity control state, and the humidity control range is the humidity setting value.
2. Humidification mode: (You can short press the setting button on the home page to view, or you can see the water drop mark on the screen, that is, the current humidification mode)
①When real-time humidity + humidity temperature difference value (OBJ HUM) ≤ target humidity value, the relay starts to work and starts to humidify
②When the humidification humidity reaches the target humidity value, the humidification relay stops working and enters the humidity control state. The humidity control range is the humidity setting value.
Timing description:
Temperature timing switch operation instructions:
①The plus button controls the temperature timing, short press to view the timing to turn on or off the target temperature, long press the plus button to turn on the timing
②In the home page interface, short press the plus button to display one one: one TEMP (for temperature timing shutdown) long press the plus button to turn off the target temperature, when the long press starts, XX:XX TEMP will be displayed
③In the home page interface, short press the plus button to display (for the temperature timing start) long press the plus button to start the target temperature regularly, when the long press starts, it will display XX:XX time
Humidity timer switch operation instructions:
①The minus button controls the humidity timing, short press to view the timing on or off the target humidity, long press the minus button to turn on the timing
②In the homepage interface, short press the minus button to display one one: one HUM (currently humidity timer shutdown), immediately press and hold the plus button to turn off the target temperature, when the long press starts, it will display XX:XX HUM
③In the homepage interface, short press the minus button to display –:– (currently the humidity is in the timing power on state) immediately press and hold the plus button to turn on the target temperature, and when the long press starts, XX:XX time will be displayed

Menu description:

Key Description:

Key Description:

1. Power button:

①Long press the switch

②In the setting mode, short press is the confirmation key

2. Setting key:

①Short press to view the temperature control mode, short press again to view the humidity control mode

②Long press to enter the setting interface, and short press the setting key to select

Select temperature control and humidity control or time mode (ie P, F and H mode switching)

3. Add key:

①On the homepage, short press to view the target temperature switch time, long press to turn on

Target temperature switching time

②In the menu mode, short press and 1 long press and continue to add

4. Minus key:

①On the homepage, short press to view the target humidity switch time, long press to turn on the target humidity switch time

②In the menu mode, short press to decrease 1 long press to continue to decrease

5. Combination key:setting key + number minus (restore factory settings)

In the power-on state, long press the key combination at the same time will restore the factory settings

Mode description:

Manual heating and cooling in temperature control mode and humidification and dehumidification in humidity control mode
Go to set

Temperature control mode:

1. Refrigeration mode:(You can short press the setting button on the home page to view, or you can see on the screen

Snowflakes sign, that is, the current cooling mode)

①When real-time temperature ≥ target temperature setting value (OBJ TEMP) + temperature difference setting

It enters the refrigeration state when the value is reached, the relay works and starts refrigeration.

②When the real-time temperature drops to the target temperature setting value (OBJTEMP), the cooling

The relay stops working, the thermostat enters the temperature control state, and the temperature control range is the temperature difference setting

value.

③When real-time temperature ≥ target temperature setting value (OBJ TEMP) + temperature difference again

When the set value is set, the thermostat enters the compressor delay state, and the refrigeration relay after the compressor delay expires

The device just started working.

2. Heating mode:(You can short press the setting button on the homepage to view, or you can see on the screen.

Sun sign, that is, the current heating mode)

① When the real-time temperature ≤ target temperature setting value-temperature difference setting value, enter heating

State, the heating relay works.

②When the heating temperature reaches the target temperature value, the heating relay stops working,

The thermostat enters the temperature control state, and the temperature control range is the temperature difference setting value.

2. Humidity control mode:

1. Dehumidification mode:(You can short press the setting button on the home page to view, or you can see it on the screen

No water drop sign, that is, the current dehumidification mode)

①When the real-time humidity and humidity temperature difference value (OBJ HUM) ≥ the target humidity value, continue

The appliance starts to work and begins to dehumidify

②When the dehumidification humidity reaches the target humidity value, the dehumidification relay stops working,

Enter the humidity control state, and the humidity control range is the humidity setting value.

2. Humidification mode:(You can short press the setting button on the home page to view, or you can see on the screen

Water drop mark, that is, the current humidification mode)

①When real-time humidity + humidity temperature difference value (OBJ HUM) ≤ target humidity value, continue

The appliance starts to work and starts to humidify

②When the humidification humidity reaches the target humidity value, the humidification relay stops working,

Enter the humidity control state, and the humidity control range is the humidity setting value.

Timing description:

Operating instructions for temperature timer switch:

①Add the key to control the temperature timing, short press to view the timing on or off the target temperature

, Long press the plus key to start timing

②In the home page interface, short press the plus key to display one one: one TEMP (for

(Temperature timer shutdown) Long press the plus key to turn off the target temperature regularly, and it will display when the long press starts

XX:XX TEMP

③In the home page interface, short press the plus key to display

(For Wen

(Turn on at a fixed time) long press the plus button to turn on the target temperature regularly, and it will display when the long press starts

XX:XX time

 

Item Specifics For More details Contact 0805 555 5061
Measure Type:
K
Cable Length:
1M
Type:
K
Theory:
Temperature Controller
Usage:
Indoor
Model Number:
W1212 Temperature Humidity Controller
Max Measuring Temperature:
120°C & Above
Display Type:
DIGITAL
Power Type:
Charger
Display Size:
1.9 Inches & Under
Brand Name:
Gaqqee
Origin:
Mainland China
Certification:
CE