1. The starting power of inductive load electrical appliances shall be at least three times of the rated power of the electrical appliances. If the starting power exceeds the inverter power, the inverter may be damaged. Please select a suitable model before purchasing.
2. Please connect the circuit correctly according to the instructions, and install switches for each circuit.
3. Starting sequence: first turn on the battery switch, start the inverter, and turn on the PV, mains and load switches.
4. Shutdown sequence: turn off the switches of load, PV and mains, turn off the inverter, and finally turn off the battery.
Please find an electrician to install the inverter. Installing it yourself can cause danger or damage to the equipment.
The AN-SCI02 Pro series all in one solar system is the perfect go-to solution for off-grid, backup power for homes, small business, and it also delivers a value added, easy to install system that provides efficient power globally for every need.
Key Features:
◆ Pure Sine Wave Inverter
◆ Configurable input voltage range for home appliances and personal computers via LCD setting
◆ Configurable AC Solar Charger priority via LCD setting
◆ Compatible to mains voltage or generator power
◆ Auto restart while AC is recovering
◆ Overtload/ Over temperature/ short circuit protection
◆ Smart batterγcharger design for optimized battery performance
◆ Communicate with WIFI
◆ System configures quickly into compact, wall-mounted system.
Model |
SCI02-Pro-3600 |
SCI02-Pro-6200 |
|
RATED POWER |
3600W |
6200W |
|
INPUT |
|||
Voltage |
230 VAC |
||
Selectable Voltage Range |
170-280 VAC (For Personal Computers) |
||
90-280 VAC (For Home Appliances) |
|||
Frequency Range |
50 Hz/60 Hz (Auto sensing) |
||
OUTPUT |
|||
AC Voltage Regulation (Batt. Mode) |
230VAC ± 5% |
||
Surge Power |
7200VA |
12400VA |
|
Efficiency (Peak) PV to INV. |
97% |
||
Efficiency (Peak) Battery to INV. |
94% |
||
Transfer Time |
10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
||
Waveform |
Pure sine wave |
||
BATTERY & AC CHARGER |
|||
Battery Voltage |
24 VDC |
48 VDC |
|
Floating Charge Voltage |
27 VDC |
54 VDC |
|
Overcharge Protection |
33 VDC |
63 VDC |
|
SOLAR CHARGER |
|||
Maximum PV Array Power |
6200 W |
6500 W |
|
MPPT Range @ Operating Voltage |
90 ~ 450 VDC |
||
Maximum PV Array Open Circuit Voltage |
500 VDC |
||
Maximum Charging Current |
120A |
120A |
|
Maximum Efficiency |
98% |
||
Grid-Tie Operation |
|||
Inverter Mode |
3600W |
6200W |
|
Nominal Output Voltage |
220/230/240VAC |
||
Feed-in Grid Voltage Range |
195-253VAC |
||
Feed-in Grid Frequency Range |
49-51±1Hz/59-61±1Hz |
||
Nominal Output Current |
15.7A |
26.9A |
|
Power Factor Range |
>0.99 |
||
PHYSICAL |
|||
Dimension, D x W x H (mm) |
100 x 300 x 444 |
||
Net Weight (kgs) |
10 |
11 |
|
Communication interface |
WIFI |
||
OPERATING ENVIRONMENT |
|||
Humidity |
5% to 95% Relative Humidity(Non-condensing) |
||
Operating Temperature |
0°C – 55°C |
||
Storage Temperature |
–15°C – 60°C |
Key Features:
◆ Pure Sine Wave Solar Hybrid Inverter;
◆ Be able to run without battery;
◆ One-key restoring to factory default settings;
◆ PV automatically activates lithium batteries;
◆ Bulit-in MPPT solar controller, max charge current 120A;
◆ Max 6200W & 6500W solar input power respectively;
◆ Wide PV input voltage range (90-450VDC);
◆ Built-in anti-dusk kit for harsh environment.
◆ Smart battery charge design to maximize battery lifespan
◆ Dual AC output;
◆ WIFI available for IOS and Android systems.
NVERTER MODEL |
SCI-ECO-4.2KW |
SCI-ECO-6.2KW |
Inverter Mode Specifications |
||
Rated Output Power |
4.2KW |
6.2KW |
Output Voltage Waveform |
Pure Sine Wave |
|
Output Voltage Regulation |
230Vac±5% |
|
Output Frequency |
50Hz |
|
Peak Efficiency |
93% |
|
Overload Protection |
3s@≥150%load; 5s@101%~150% load |
|
Surge Capacity |
2* rated power for 5 seconds |
|
Nominal DC Input Voltage |
24Vdc |
48Vdc |
Cold Start Voltage |
23.0Vdc |
46.0Vdc |
No Load Power Consumption |
35W |
50W |
Two Load Output Power |
||
Full Load |
4200W |
6200W |
Maximum Main Load |
4200W |
6200W |
Maximum Second Load(battery model) |
1400W |
2066W |
Main Load Cut Off Voltage |
22VDC |
44VDC |
Main Load Return Voltage |
26VDC |
52VDC |
Charge Mode Specifications |
||
Utility Charging Mode |
||
Charging Algorithm |
3-Step |
|
AC Charging Current (Max) |
100Amp |
|
Floating Charging Voltage |
27Vdc |
54Vdc |
MPPT Solar Charging Mode |
||
Max. PV Array Power |
6200W |
6500W |
Nominal PV Voltage |
240Vdc |
360Vdc |
PV Array MPPT Voltage Range |
60Vdc~500Vdc |
|
Max. PV Array Open Circuit Voltage |
500Vdc |
|
Max Charging Current |
120Amp |
|
Grid-Tie Operation |
||
Nominal Output Voltage |
220/230/240 VAC |
|
Feed-in Grid Voltage Range |
195~253VAC |
|
Feed-in Grid Frequency Range |
||
Nominal Output Current |
18.2A |
26.9A |
Power Factor Range |
>0.99 |
|
Maximum Conversion Efficiency (DC/AC) |
97% |
|
General Specifications |
||
Safety Certification |
CE |
|
Operating Temperature Range |
–10°C – 50°C |
|
Storage temperature |
–15°C – 60°C |
|
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
|
Dimension, D x W x H (mm) |
110*334*423 |
|
Net Weight (kgs) |
9.5 |
10 |
Explanation of Advantages of Hybrid Inverter Dual Outputs:
The inverter adopts a dual output mode: the main output can be connected to a rated power load, and the secondary output can be connected to a load of one-third of the rated power (subject to the specifications for details)
Dual output function description:
The main and secondary outputs are used in normal condition. But in the following two conditions, the main output is disconnected and only the secondary output is retained:
– when there is no solar power input and mains power input;
– when the battery voltage is lower than 44V (the minimum can be set to 41V, and the maximum can be set to 46V);
Advantages of dual output:
In a power generation system using lithium batteries for storage, when the inverter is under full load or high-power load, due to the characteristics of lithium batteries, the battery voltage tends to drop too quickly, which shall make the battery voltage too low and disconnect the battery while the battery bank still keeps 50% of rated power.
With the dual output function, user can connect some important loads to the secondary output. When the battery voltage is low (typically lower than 44V, with a minimum setting of 41V), the inverter shall disconnect the main load and ensure the output of the secondary load, which can extend the operation time of the secondary load.
FEEDBACK
We will try to provide you with good service.
1.lf you have any question, please kindly contact us via Aliexpress message, we will reply you within 24 hours;
2.We would be grateful if you would contact us before leaving 1-3 stars feedback. we will take pleasure to provide you a satisfactory solution.
Sincerely wish you have a good shopping time and hope can bring you more happy time.
4 GREAT REASONS TO BUY FROM US:
- Over 37,000 happy customers worldwide
- Real people on our support team ready to help
- The finest materials and stunning design — all our products are developed with an obsessive dedication to quality, durability, and functionality
- We use the most secure online ordering systems on the market, and are constantly improving our software to make sure we offer the highest possible security
BUY WITH CONFIDENCE
Our mission is to make your shopping experience as safe and enjoyable as possible. Have questions? Feel free to contact our award-winning customer care team for advice on everything from product specifications to order tracking.
- Money back guarantee: Something not quite right? If you’re not totally satisfied with your purchase, you can return it within 15 days for a full refund
- Risk-Free Purchase: We utilize industry-standard Secure Sockets Layer (SSL) technology to allow for the encryption of all the sensitive information, so you can be sure your details are completely safe with us
- Trustworthy payment method: We partner with the most popular online payment solutions that guarantee enhanced security and fast transaction processing