Daxtromn 6.2KW Hybrid Solar Inverter 48V 500VDC 120A MPPT Solar Charger 6200W Solar Hybrid Inverter Pure Sine Wave 220V With BMS
Feature Of AGH-6.2KW-BMS Hybrid Solar Inverter
1.Pure Sine Wave Solar Inverter
2.Max 120A MPPT Solar Charger
3.Max 500VDC PV Input
4. 2 Loads Output,Support BMS
5.High PV input voltage range(120~450VDC)
6.Output power factor 1.0
7.Real Hybrid Solar inverter for 24V/48V system
8.Wifi Module for easily connection
9.Efficiency work with or without battery
10.Bundled monitoring & setting software
11.Supports 50hz or 60hz (program adjustable)
12.Able to use ac grid or generator power
13.Built-in anti-dusk kit for harsh environment
14.Optional DC output for DC fan, LED bulb,router and so on
What is 2AC out function?
DO NOT CONNECT THE SECOND OUTPUT TO THE GRID,IT WILL DAMANGE YOUR INVERTER
What is the BMS model?
Difference between BMS and without BMS:
If the battery has BMS, after plugging in the BMS, the inverter and the battery will communicate and automatically adjust the charging voltage cut-off voltage and other parameters, and various parameters will be adjusted at any time according to the condition of the battery, which will be a higher level for the life of the battery and the safety of use.
The inverter and battery need to have BMS functions at the same time to communicate with each other.
Specification Of 6200W Hybrid Solar Inverter
Model |
AGH-4.2KW-BMS |
AGH-6.2KW-BMS |
Phase |
1-Phase |
|
Maximum PV Input Power |
6200W |
6500W |
Rated Output Power |
4200W/4200VA |
6200W/6200VA |
Maximum Solar Charging Current |
120A |
|
GRID-TIE OPERATION |
||
PV Input(DC) |
||
Nominal DC Voltage/Maximum DC Voltage |
360VDC/500VDC |
|
Start-up Voltage/Initial Feeding Voltage |
90VDC/120VDC |
|
MPPT Voltage Range |
90~450VDC |
|
Number of MPPT/Max Input Current |
1/22A |
|
GRID OUTPUT(AC) |
||
Norminal Output Voltage |
220/230/240VAC |
|
Output Valtage Range |
195.5~253VAC |
|
Norminal Output Current |
15.7A |
27.0A |
Power Factor |
>0.99 |
|
Feed-in Grid Frequency Range |
49~51±1Hz |
|
EFFICIENCY |
||
Max Conversion Efficiency(Solar to AC) |
98% |
|
TWO LOAD OUTPUT POWER(V2.0) |
||
Full Load |
4200W |
6200W |
Maximum Main Load |
4200W |
6200W |
Max Second Load(battery mode) |
1200W |
2067W |
Main Load Cut Off Voltage |
22VDC |
44VDC |
Main Load Return Voltage |
26VDC |
52VDC |
OFF-GRID OPERATION |
||
AC Input |
||
AC Start-up Voltage/Auto Restart Voltage |
120-140VAC/180VAC |
|
Acceptable Input Voltage Range |
90-280VAC or 170-280VAC |
|
Maximum AC Input Current |
30A |
40A |
Nominal operating frequency |
50/60Hz |
|
Surge power |
7200W |
12400W |
BATTERY MODE OUTPUT(AC) |
||
Nominal Output Voltage |
220/230/240VAC |
|
Output Waveform |
Pure sine wave |
|
Efficiency(DC to AC) |
94% |
|
BATTERY&CHARGER |
||
Nominal DC Voltage |
24VDC |
48VDC |
Maximum Solar Charging Current |
120A |
|
Maximum AC Charging Current |
100A |
|
PHYSICAL |
||
Dimension,D*W*H(mm) |
110*334*423 |
|
Net Weight(Kgs) |
9 |
10 |
INTERFACE |
||
Communication Port |
RS232/WIFI/RS485 |
|
ENVIRONMENT |
||
Operating Temperature |
-10~50℃ |