Dropship MH1210W 12V 24V AC 110-220V 10A LED Digital Thermometer Thermoregulator Temperature Controller NTC Probe Incubator
MH1210W
Specifications:
1. Voltage: AC 90-250V / DC 9-72V
2. -40C ~120C: Measurement error +- 0. 5 C
3. -40C~120C: Temperature control accuracy: 1C display accuracy 0. 1C
4. NTC25C=10K B3435 Soil 1% (1 meter long, regardless of positive or negative)
5. Power supply voltage: DC version is DC12~72V, AC version is AC100/220V
6. Working environment: Temperature: -20 C ~ 70 C, humidity: 90% RH no condensation
7. Product size: 75*85*35 (width, depth, height) mm
Instructions:
Press the S key for 3 seconds to enter the program menu code mode, which displays the code HC. Press the ” or ” key to cycle through the HC-CP-LA-PU-CA parameters. To enter a code, press the S key, press the ” or ” key to change the desired value and press SET to save and exit. . Control temperature setting: Short press S key (not more than 2 seconds) to display the factory default control temperature. Press ” or ” key to change the value well to save automatically. (Press and hold the ” or ” key for 2 seconds to quickly adjust the value.)
Heating control:
When the temperature control method (code HC) is set to H, for example, the set control temperature value is 28 C, and the temperature difference is 2 C. When the ambient temperature value ≥ the set temperature value (28 C), the relay opens and closes the output load; when the ambient temperature value ≤ the set temperature value (28 C) – the return temperature (2 C and the “delay” is set After the start time, the relay pulls up to start the output load; (if the delay function is not needed, the delay start (code PU) can be set to 0).
Cooling mode:
When the temperature control method (code HC) is set to C, for example, the set control temperature value is 28 C, and the temperature difference is 2 C. When the ambient temperature value = set temperature value (28 C) + hysteresis temperature (2 C) and the “delay start” is set After the time, the relay is sucked and the output load is started: (It is recommended that the delay start time is the default time to protect the compressor. If no delay is required, the code (PU) is set to 0)
STC1000