Switch the modes between cool and heat;
Control temperature by setting the temperature setting value and the difference value;
Temperature calibration;
Refrigerating control output delay protection;
Alarm when temperature exceeds temperature limit or when sensor error.
Technical Parameters:
Temperature measuring range: -50~99 Celsius
Accuracy: 0.1 Celsius
Sensor error delay: 1 minute
Power supply: DC 12V, DC 24V, 110V/220V AC+10%, 50/60Hz
Power consumption: <3w
Sensor: NTC sensor(IPC)
Relay contact capacity: Cool (10A/220VAC); Heat (10A/220VAC)
Ambient temperature: 0-60 Celsius
Storage temperature: -30-75 Celsius
Relative humidity: 20-85%(No condensate)
Indicator light status instruction:
Indicator light |
Function |
Cool indicator light |
On:Refrigeration starts;Off:Refrigeration stops;Flash:compressor delay |
Heat indicator light |
On: heating starts;Off:heating stops |
Set indicator light |
On:parameter setting status |
Key operation instruction:
1. View parameter method: When the controller is working normally, press and release the “▲” button once, display the temperature set value, press and immediately release the “▼” button once to display the temperature difference set value, 2 seconds return to normal temperature display state
2. Set the parameter method
When the controller is working normally, press and hold the “S” button for more than 3 seconds to enter the modified parameter mode,
The indicator light is on, and the digital tube displays the code “F1” of the first menu item.
Press “▲” or “▼” to scroll up or down the menu item and display the menu code, press “S”
The key displays the parameter setting value of the current menu. Hold down the “S” key and press and hold “▲” or “
the key can be adjusted up or down and the parameter setting value of the current menu is displayed, while holding down “S” and “▲”
The key or “▼” key can quickly up or down and display the parameter settings of the current menu.
After the completion, press and release the power button to save the parameter modification and return to the normal temperature display state.
If there is no key operation within 0 seconds, the parameter modification will not be saved and return to the normal display state.
“Er” is displayed if an error occurs while saving the parameter, and returns to the normal display state after 3 seconds.
3.Repair system data
When the machine is powered on, first check whether the parameter setting is normal. If the check is wrong, it will display “ER”. Pressing any key at this time will restore the default parameter settings and work normally. It is recommended to reset the parameters at this time.
Operation instruction:
Under controller normal working status, press and hold “ ” key for 3s can turn off the controller; Under controller “off” status, press and hold “ ” key for 3s can turn on the controller.
Under the controller normal working status, screen displays the current temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature ≥ temperature set value + difference value, and the refrigerating relay is connected; The “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature ≤ temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value ≤ the temperature set value-difference value, and the “Heat” indicator light on, and the heat relay connects; When the measuring temperature ≥ temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.
Menu instruction:
Code |
Function |
Set range |
Default |
F1 |
Temperature set value |
-50~99℃ |
10℃ |
F2 |
Difference set value |
1~10℃ |
3℃ |
F3 |
Compressor delay time |
1~10 minutes |
3 minutes |
F4 |
Temperature calibration value |
-10℃~10℃ |
0℃ |
F5 |
Fahrenheit/Celsius switching |
Set range |
0/1 |
Error description:
Alarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all the running status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm function when the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzer alarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.
Safety Regulations:
★Danger:
1.Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong
connections or overloading the relay.
2.Dangers: Prohibit connecting the wire terminals without electricity cut-off.
★Warning:
Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or
strong corrosion.
★Notice:
1.The power supply should conform to the voltage value indicated in the instruction.
Code |
Function |
Set Range |
Default |
P0 |
Compressor 1 delay time |
0-60min |
0min |
P1 |
Compressor 2 delay time |
0-60min |
0min |
P2 |
High temperature alarm value |
55-120 ° C |
120 ° C |
P3 |
Low temperature alarm value |
55-120 ° C |
-55 ° C |
4 GREAT REASONS TO BUY FROM US:
- Over 37,000 happy customers worldwide
- Real people on our support team ready to help
- The finest materials and stunning design — all our products are developed with an obsessive dedication to quality, durability, and functionality
- We use the most secure online ordering systems on the market, and are constantly improving our software to make sure we offer the highest possible security
BUY WITH CONFIDENCE
Our mission is to make your shopping experience as safe and enjoyable as possible. Have questions? Feel free to contact our award-winning customer care team for advice on everything from product specifications to order tracking.
- Money back guarantee: Something not quite right? If you’re not totally satisfied with your purchase, you can return it within 15 days for a full refund
- Risk-Free Purchase: We utilize industry-standard Secure Sockets Layer (SSL) technology to allow for the encryption of all the sensitive information, so you can be sure your details are completely safe with us
- Trustworthy payment method: We partner with the most popular online payment solutions that guarantee enhanced security and fast transaction processing