STC-8080A+ STC-1000 STC-3028 Digital Refrigerator Thermostat Temperature Controller Refrigeration Thermoregulator Incubator

16-31 days
Quantity:
In Stock
View Cart
Guaranteed safe checkout
Product/Services Details - For Bulk purchase Contact 0805 555 5061
Item Specifics For More details Contact 0805 555 5061
Product/Services Details - For Bulk purchase Contact 0805 555 5061

STC-8080A+:

Description:

STC-8080A+ is a universal single-sensor temperature controller, with functions such as refrigeration, defrosting, and temperature over-limit alarm. Compressor protection can be cured for 3 minutes.

Multiple functions and wide application range, refrigeration industry can be used for cold storage, refrigerated cabinet, temperature control on the occasion of the ocean pool, can also be used for other occasions of automatic temperature control.

Specifications:

Model: STC-8080A+

Power supply voltage: 220VAC+10%/-15%,50/60Hz

Power consumption: </= 3W

Temperature measuring range :-50°C to 99 °C

The temperature range is :-40°C to 50 °C

Measurement accuracy: 1 °C

Accuracy:±1 °C (-40 to 50 °C), ±2°C (Other)

Relay capacity of compressor:7V/220VAC, 

Relay capacity of defroster:7V/220VAC

Sensor error relay time :1 minute

Sensor type :NTC sensor

Sensor length:1 meter

Front panel safe level :IP64

Operating temperature:0°C – +60°C

Relative humidity :20%-85%( No condensate )

Storage temperature:-30°C – 75°C

STC-1000:

Features:
100% brand new and high quality
modle: STC-1000
Switch the modes between cool and heat; Control temperature by setting the temperature setting value and the difference value; Temperature calibration; Refrigerating controloutput hello kitty elay protection; Alarm when temperature exceeds temperature limit or when sensor error.

Technical Parameters:
1.Temperature measuring range: -50 ° C ~ 99 ° C
2.Resolution: 0.1 ° C;
3.Accuracy:+- 1° C (-50 ° C ~ 70 ° C);
4.Sensor error delay: 1 minute
5.Power supply: AC 110-220V 50/60Hz,  DC 12V, DC 24V, DC12-72V( Choose power supply when you place order ) ;
6.Power consumption: <3W;
7.Sensor: NTC sensor (1PC);
8.Relay contact capacity: Two Relay Cool 10A/220VAC; Heat 10A/220VAC;
9.Ambient temperature: 0 ° C ~ 60 ° C;
10.Storage temperature: -30 ° C ~ 75 ° C;
11.Relative humidity: 20% ~ 85% (No condensate)
12.Sensor length: 1.0m
13. Front Panel Size: 75×34.5mm ; Product Size: 75×34.5×85 mm ; Mounting Size: 71x29mm

Key operation instruction

1 .The way to check parameter:

Under normal working status, press “up” key it displays temperature setting value; press “down” key it displays the difference value.

2. The way to set parameter:

Under controller normal working status, press “s”key for 3s or more to enter parameter modifying mode, and the “Set” indicator light on, screen displays the first menu code “F1”.

Press “up”key or “down” key to adjust up and down and display the menu iem and the code of the menu item.Press “s” key to display the parameter value of the current menu. Press both “s”key and hold “up”key or “down” key simultaneously to choose and adjust the parameter value of the current menu value promptly. After finishing the setting, press and release the “(I)” key instantly to save the parameter modified value and return to display the normal temperature value. If no key operation within 10 seconds, system won't save modified parameter, screen back to display normal temperature.

3. Restore system data

When electrified, system will check itself, screen will display “Er” if error exit, please press any key at this time, and it restores default value and enter into normal working mode, it is advised to reset the parameter value under such conditions.

Operation instruction
Under controller normal working status, press and hold “(I)”key for 3s can turn off the controller; Under controller “off” status, press and hold “(I)” key for 1s can turn on the controller.
Under the controller normal working status, screen displays the current measuring temperature value; also the controller can also switch the working mode between heating and cooling.
Controller starts refrigerating with cool indicator light on when the measuring temperature value >= temperature set value + difference value, and the refrigerating relay is connected; If the “Cool” indicator light flashes, it indicates the refrigerating equipment is under compressor delay protect status; when the measuring temperature values temperature set value, the Cool indicator light on, and refrigerating relay disconnects.
System starts heating when the measuring temperature value = temperature set value, the “Heat” indicator light is off, and the heat relay disconnects.

Error/Alarm description

Alarm when sensor error: Controller activate the sensor error alarm mode when sensor open circuit or short circuit, all therunning status is closed off with the buzzer alarms, and the nixie tube displays “EE”,Press any key can cancel alarm sound, system back to display the normal temperature when the error and the fault is cleared.

Alarm when the measuring temperature exceeds temperature measuring range:Controller activates the error alarm functionwhen the measuring temperature exceeds the temperature measuring range, all the running status is closed off with the buzzeralarms, and the nixie tube displays “HH”,Press any key can cancel alarm sound, system back to display the normal working mode when the temperature restore to normal measuring range.

Safety Regulations

★Danger:

1.Strictly distinguish the sensor down-lead, power wire and output relay interface from one another, and prohibit wrong

connections or overloading the relay.

2.Dangers: Prohibit connecting the wire terminals without electricity cut-off.

★Warning:

Prohibit using the machine under the environment of over damp, high temp., strong electromagnetism interference or

strong corrosion.

★Notice:

1.The power supply should conform to the voltage value indicated in the instruction.

2.To avoid the interference, the sensor down-lead and power wire should be kept a distance.

Package Included:
1 * Temperature Controller
1 * Temperature sensor

STC-3028:

Be able to control temperature and humidity at the same time.
Be able to connect with refrigeration/ heating and humidifier/dehumidifier equipment at the same time.
Heating/Cooling function could be set separately for refrigeration and heating to protect temperature controller from violent change.Same as humidity Control.
Supporting Temp and Humidity Calibration
Dual Display Window,Be able to display measured temperature/humidity and set temp/humidity at the same time
Specification:
Model: STC-3028
Input voltage: AC110~220V, DC24V, DC12V
Measuring temperature range: -50°~+110°
Measuring humidity range: 00%RH~+100%RH
Accuracy: ±1°, 0.1%RH
Relay output contact capacity: 10A/240VAC
Shell material: PC + ABS fireproof
Sensor length: 1m
Set startup temperature(humidity):
Press the “up” button once to display the starting temperature(humidity). Long press the “up” button for about 3 seconds,The required temperature(humidity) can be set by the up and down keys
Set the stop temperature(humidity):
Press the “down”button once to display the stop temperature(humidity). Long press the button for about 3 seconds and the stop temperature(humidity) number flashes. The required temperature(humidity) can be set by the up and down keys
temperature(hunidity)correction:
Press”up” and “down button at the same time.

Item Specifics For More details Contact 0805 555 5061
Brand Name:
XMSJ
Origin:
Mainland China
Usage:
Industrial
Display Size:
1.9 Inches & Under
Cable Length:
1m
Certification:
CE
Feature:
Heating Cooling thermostat regulator
Use:
various sensor control boxes for water heater freezer fan
Top

Shopping cart

×