Model: W1088
Temperature measurement range: -50°C ~ 120°C
Resolution: 0.1°C
Accuracy: ±1°C
Sensor length: 1m
Output type: direct output 10A
Voltage specification: 12V 24V AC110-220V
How to set the heating/cooling mode
Heating setting essentials:
Heating setting essentials:
Start temperature < stop temperature (the program automatically determines that the working mode is the heating mode)
How to set:
Long press the up button, the startup temperature will flash, and use the up and down buttons to set the startup temperature value.
Long press the adjustment button to stop the temperature flashing, and use the up and down buttons to set the stop temperature value.
Cooling mode setting method:
Start temperature > stop temperature (the program automatically determines that the working mode is the cooling mode)
How to set:
Long press the up button, the startup temperature flashes, and the startup temperature value is set by the up and down buttons.
Press and hold the adjustment button to stop the temperature flashing, and use the up and down keys to set the stop temperature value.